• COMPANY
  • BUSINESS
  • DATA
  • SUPPORT
 






 
> COMPANY >Burner
  F Type Gas/Oil Dual Fuel Burner - Duobloc
Gas Oil Dual
 

 

Model Max. CapacityVersion Boiler Capacity
(T/H)
Gas Press Gas Piping(Inch) RDL
(mmAq)
kcal/h mmAq
F9OLN 2,100,000 1 ~ 2 4000 50A 140
F11OLN 2,940,000 2.5 ~ 3 4000 50A 160
F15OLN 4,200,000 4 ~ 5 4000 50A 180
F16OLN 6,300,000 6 ~ 7 4000 50A 180
F18OLN 7,900,000 8 4000 65A 200
F20OLN 8,700,000 10 4000 65A 200
F22OLN 12,500,000 15 4000 80A 200
WS55OLN 16,800,000 20 Option 100A 200
WS80OLN 21,000,000 25 Option 100A 200
WS90OLN 25,200,000 30 Option 100A 200

Note)
1. RDL : When burners are matched with the recommended boiler capacity.
2. Air/Fuel Ratio control
: Mechanical linkage type or
Electronic control by separately installed motors to air and to fuel are applicable on request.
3. Atomizing Method
: Mechanical Pressure Jet type or
Steam/Air Jet type iiar4e applicable on request.
4. Pumping Unit
- 1 pump system
- 2 pump system
For heavy oil application, Pumping & Heating Unit shall be installed.
5. For detailed specifications and applications, please contact us.