• COMPANY
  • BUSINESS
  • DATA
  • SUPPORT
 






 
> COMPANY >Burner info
   
  NFK Burner
 

 

 
NFK-CBU Gas Burner
Applications
- Smoke Tube Boilers
- Water Tube Boilers
- Electric Power Generation Boilers
- Hot OIL Heaters
- Gas Turbine exhaust Afterburner
- Air Heaters & Incinerators

Advantages
1. Comparable to applications and fuel gas types
(Center fire type, Ring Type, Multi-Spud type and Scroll type burners)
2. Applicable with various gas supply condition
3. Wide Turn Down Ratio
4. Draft Loss at Burner Max. 1.5kPa(150mmAq)
5. Low O2 and dust in exhaust gas
6. Various Multi-fuel combustion(Gas-Gas, Gas- Liquid)

Performance and Specifications
1. Turn Down Ratio 8 ~ 10 : 1
2. Gas Burner Type
Condition Gas Burner Type
CENTER FIRE RING MULTI SPUD SCROLL
Kind of Gas Town Gas Town Gas Town Gas BFG
LNG LNG LPG LDG
Hydrogen Hydrogen REFINERY GAS CPG
Others Other Clean Gas Others Others
L.C.V.
kcal/Nm3
2,000 ~ 30,000 2000 ~ 12,000 2000 ~ 30,000 Less than 5000
Type of Combustion Gas Comb. Gas Comb. Gas Comb. Gas Comb.
Switched Combustion Switched Combustion Switched Combustion Switched Combustion
  Multi Fuel Combustion Multi Fuel Combustion Multi Fuel Combustion
 
NFK-CBU Oil Burner
Applications
- Smoke Tube Boilers
- Water Tube Boilers
- Electric Power Generation Boilers
- Hot OIL Heaters

Advantages
1. Better Atomization due to steam(air) intermixing burner
2. Applicable with wide range of fuel
3. Low Fuel pressure at burner max. 1MPa(10 kg/cm2)
4. Wide Turn Down Ratio
5. Draft Loss at Burner Max. 1.5kPa(150mmAq)
6. Low O2 and dust in exhaust gas
7. Various Multi-fuel combustion(Liquid-Liquid, Gas- Liquid)

Performance and Specifications

1. Turn Down Ratio 8 ~ 10 : 1
2. Atomizing Medium
. Steam : Min. 0.6MPa(6kg/cm2)
Steam Consumption 0.1 ~ 0.15kg/kg-oil
(Saturated ans superheated steam)
. Air : Min. 0.6MPa(6kg/cm2)
Air Consumption 0.2 ~ 0.3Nm3/kg-oil
3. Combustion air temperature : Max. 300C
4. Capacity Range : 500,000 ~ 45,000,000kcal/h
 
NFK-ULN Low NOx Gas Burner
Applications
- Smoke Tube Boilers
- Water Tube Boilers
- Electric Power Generation Boilers
- Hot OIL Heaters

Advantages
1. Low NOx gas burner(Fuel Stage type)
2. Applicable to wide range of fuel
3. Wide Turn Down Ratio
4. Draft Loss at Burner Max. 1.8kPa(180mmAq)
5. Possible NOx 40PPM(O2=0%) with exhaust gas recirculation
6. Possible Multi-fuel combustion with oil fuel

Performance and Specifications

1. Turn Down Ratio 6 ~ 10 : 1
? 2. Capacity Range : 500,000 ~ 35,000,000kcal/h
 
NFK-LND Low NOx Oil Burner
Applications
- Smoke Tube Boilers
- Water Tube Boilers
- Electric Power Generation Boilers
- Hot OIL Heaters

Advantages
1. Low NOx and Low dust in exhaust gas(Self Recirculation Combustion)
2. Applicable to wide range of fuel
3. Wide Turn Down Ratio
4. Draft Loss at Burner Max. 1.8kPa(180mmAq)
5. Possible NOx 150PPM(O2=4%) at high nitrogen circumstances
6. Continuous operation with auxiliary burner
7. Possible Multi-fuel combustion with gas fuel

Performance and Specifications

1. Turn Down Ratio 6 ~ 10 : 1
2. Atomizing Medium
. Steam : Min. 0.6MPa(6kg/cm2)
Steam Consumption 0.1 ~ 0.15kg/kg-oil
(Saturated ans superheated steam)
. Air : Min. 0.6MPa(6kg/cm2)
Air Consumption 0.2 ~ 0.3Nm3/kg-oil
3. Combustion air temperature : Max. 300C
4. Capacity Range : 1,300,000 ~ 45,000,000kcal/h
 
NFK-CGT Oil & Gas Burner

Applications
- Gas Turbine exhaust Afterburner

Advantages
1. Wide Turn Down Ratio
2. Excellent Combustibility and flame stability
3. Low NOx
4. Low Draft Loss at burner
5. Smooth shifting to fresh air moide
6. Excellent afterburner, as well as converter

Performance and Specifications

1. Turn Down Ratio 6 ~ 10 : 1
2. Coimbustion Air Temperature : Max 650'C(GT Exhaust gas temperature)
3. O2 content in GT exhaust gas(combustion air) 10 ~ 21%, m=0.6
4. Capacity Range : 2,000,000 ~ 30,000,000kcal/h
 
NFK-Big Capacity burner for Low Calorific value

Applications
- Water Tube Boilers
- Electric Power Generation Boilers
- Hot OIL Heaters
- Incinerators

Advantages
1. Big capacity complete combustion under low pressure gas supply
2. Good flame stability
3. Various multi-fuel combustion(Gas-Gas, Gas-Liquid)
4. Wide turn down ratio
5. Draft Loss at burner 1.5KPa(150mmAq)
6. Possible Low NOx counter measure
7. Long life time due to raqdiation free structure

Performance and Specifications

  Low Press. Center fire type Scroll type
Capacity(Nm3/h) 500 ~ 30,000 800 ~ 45,000
Pressure at burner, Kpa 1.0~10 1.0~10
Turn Down Ratio 1:2~1:6 1:2~1:6